WOODEN BRIDGE TIME HISTORIES DATA wav-files include data matrix of size 2192 x 16 16 channels 2192 samples Variables: The first variable is force (very bad, never used) Channels 2-16 are accelerations. There were 15 sensors. Measurements: Folder may18: 1-1425 undamaged Folder may25 109-565 undamaged Folder may28 1-105 Damage scenario 1 1-20 D1 21-43 D2 44-65 D3 66-85 D4 86-105 D5 106-128 undamaged 181-273 undamaged Folder may29 1-4 undamaged 5-122 Damage scenario 2 5-24 D1 25-47 D2 48-73 D3 74-99 D4 100-122 D5 123-156 undamaged Damage scenario 1 is a point mass on the top girder between sensors 1 and 2 Damage scenario 2 is a point mass on the other top girder at the end of the girder (close to sensor 4) Damage levels: D1: 23.5 g D2: 47 g D3: 70.5 g D4: 123.16 g D5: 193.66 g Reference list using the Wooden Bridge can be found in file wooden_bridge_references.doc